The H- Injector at ANL consists of a 750
keV Cockcroft-Walton preaccelerator and a Alverez type 50 MeV
Linac. The accelerator was originally constructed as the source
of protons for the Zero Gradient Synchrotron (ZGS). The first
proton beam was extracted from the preaccelerator in 1961. The
accelerator is presently used as the injector for the Intense
Pulsed Neutron Source (IPNS), a 500 MeV rapid cycling synchrotron
with a spallation-neutron target. During most of the time since
turn-on over 15 years ago, the IPNS facility availability has
rarely dropped below 90% and has averaged 95% over the last ten
years. During the same period, the 50 MeV injector availability
has averaged 99%. Performance and improvements over the 35 year
period is discussed.
The ANL 50 MeV Injector has proven itself to be a
very versatile and reliable machine. The linac has been used as
a source of protons, H- ions, polarized protons, polarized
deuterons, and neutral particle beams during it's many years of
operation. Ground was broken for the injector in June 1959. The
first 750 keV proton beam was obtained in December 1961. The first
50 MeV protons were accelerated in the linac ten months later
in October 1962. The injector was used as the proton source for
the ZGS 12.5 GeV synchrotron until 1976 when the ZGS became the
first accelerator to utilize direct injection of H-
ions as a normal mode of operation. The last two years before
the ZGS was shut down in October 1979, were dedicated to the acceleration
of polarized protons. A Rapid Cycling Synchrotron (RCS)[1] was
developed and constructed in the mid 1970's as a proposed booster
for the ZGS. Due to the scheduled shutdown of the ZGS the booster
concept was abandoned. However, the RCS evolved into the 500 MeV
accelerator for injecting protons to the IPNS spallation-neutron
target. The linac has now supplied H- ions at a 30Hz
rate to the RCS for over 15 years. We expect to inject the 5 billionth
pulse into the RCS in late November of this year.
The layout of the IPNS accelerator system including
linac, RCS, and the spallation target is shown in Figure 1. The
preaccelerator houses the 750 kV Cockcroft-Walton power supply,
the H- ion source, and the high gradient accelerating
column. The H- ion source is a magnetron type[2] in
which negative ions are extracted directly from the hydrogen plasma
on the surface of the cathode. The extractor electrode and magnet
poles are at terminal ground and the source, including the pulsed
arc supply, pulsed hydrogen supply, and cesium supply are pulsed
to a negative 20 kV potential. After extraction, the beam is bent
90° by a magnetic dipole, focussed by three quadrupole magnets,
and injected into the high gradient column. The 750 keV beam is
transported 6 m to the linac in a beamline containing two quadrupole
triplets for beam focussing, a vertical and horizontal steering
magnet, one 200 MHz buncher, and a fast beam chopper for beam
shaping. The linac cavity is a copper clad structure 0.94 m in
diameter and 33.5 m long operating at 200.070 MHz. It was constructed
in eleven sections, which are bolted together. The linac contains
124 drift tubes, each containing a dc quadrupole magnet. Rf power
is supplied to the linac via a rectangular waveguide to a single
feedloop in the center of the cavity. A 50 MeV beam line transports
the H- beam 38 m to the RCS accelerator. Beam steering
and focussing is provided by a total of eight horizontal and two
vertical dipole magnets and sixteen quadrupole magnets.
Preaccelerator
The 750 kV power supply for the preaccelerator is a standard four stage Cockcroft-Walton. The input transformers to the four stage multiplier are driven with a 400 Hz motor generator set. There have been no failures of the high voltage transformers, rectifiers, or capacitors since construction. Parts of the regulating system have been updated but some of the amplifiers are still original.
The original ion source used to supply protons to the ZGS was a standard duoplasmatron which produced enough beam current to supply the synchrotron with a 20 mA, 100 µs pulse at a one-pulse-every-four-second rate. When we switched to H- injection, a modified duoplasmatron with a hydrogen charge exchange cell[3] was used. This source was quite adequate for supplying the ZGS with enough beam current but the RCS was close to being input limited. Also, the hydrogen flow needed in the charge exchange cell required two 30,000 l/s bulk titanium sublimator vacuum pumps in the high voltage terminal. The titanium slugs in these pumps had to be replenished every two or three weeks requiring many man-hours of maintainence. In 1983 the magnetron type H- ion source was installed. This source produces 45-50 mA, 70 µs beam pulses at a 30 Hz rate, which is more than sufficient to supply the RCS 50 MeV input requirement of 10 mA. The source has been very reliable, requiring only dissassembly and cleaning after several thousand hours of operation.
The original accelerating column was a multi-gapped
low gradient structure and required frequent cleaning to enable
it to hold the 750 kV. In 1970 a single gap high gradient column
was developed and installed, increasing the linac output capability
from 20 mA to over 40 mA. A six megohm resister in series between
the 750 kV supply and the column results in only a few second
trip during a column arc. The column arc rate averages about four
per hour. The column hasn't required dissassembly and cleaning
in nearly ten years.
Linac RF System
The rf system was the first linac amplifier built
utilizing the 7835 triode. It was the first and only amplifier
to transport the rf from the power amplifier to the cavity via
a rectangular waveguide. The 7835 cavity is not pressurized, but
we have had very few problems with voltage breakdown. We have
had continuing problems with blocking capacitor voltage punch-through.
These failures seem to come in bunches every several years. Presumably
the cause is a void or foreign particle in the irrathene insulation.
Besides upgrading most of the power supplies to accomodate the
30 Hz rep-rate, the only major changes in the rf system have been
with the plate modulator for the 7835. The modulator has been
redesigned and replaced twice due to problems with output switch
tube voltage holding capabilities. The tube we have been using
for the past 15 years is the ML7560. The tube lifetime has been
excellant, over 25,000 hours, and the arc through rate is maybe
one per week.
Linac Cavity
The ANL linac was patterned after the 50 MeV Brookhaven Alternating Gradient Synchrotron (AGS) linac, with the main difference being that the quadrupole magnets in the 124 drift tubes are dc instead of pulsed. Originally each magnet had a transistorized shunt attached for individual control. Presently, transistorized shunts are utilized on only the first 58 magnets. The cavity vacuum system started out with nine 2000 l/s ion pumps and one 20" mercury diffusion pump for pump-down. The present system uses seven ion pumps, two cryo-pumps and a 1500 l/s turbo-pump. The ion pumps in use are the original pumps. We try to overhaul at least one per year which means each pump operates about 7 years before removal and cleaning.
To keep gas stripping of the H- beam at
a minimum, we try to keep the cavity vacuum below 5 x 10-7
Torr. We have an ongoing problem involving water leaks into the
linac high vacuum system. There are 57 water cooled tuning balls
mounted along the length of the linac. These are 14 cm diameter
copper balls both threaded and silver soldered to a 2.54 cm stainless
tube which extends through the cavity wall. A smaller diameter
water distributor tube runs down the center of the 2.54 cm tube
to supply water for cooling the copper ball. Water leaks (apparently
through the threaded and silver soldered joints) into the cavity
vacuum have developed over the years in 15 of these tuning balls.
A method of repairing these leaks without removing the tuning
ball or breaking the linac vacuum was developed. A smaller diameter
cooling tube is placed inside the original tube making good thermal
contact with the inside of the ball to allow for sufficient heat
removal. The space between the tubes, which now contains the leak,
is evacuated, virtually eliminating what would now be an air leak
into the cavity. We presently have a water leak in one of the
tuning balls so small that we have yet to locate it.
In 1973, the first high energy polarized proton beam[4] was developed at the ZGS. It operated very successfully until 1979 when the ZGS was shut down permanently. The source was installed in a new preaccelerator located just west of the original as shown in Figure 1. To house the large polarized proton source, a high voltage terminal 2.5 m x 3.5m x 4.5 m in size was required. The terminal was built by a company that manufactures campers. The source weighed over 4,500 kg and consumed over 35 kW of electrical power. It contained three rf systems; six magnets; six beam line elements; and nine vacuum pumps including diffusion, ion, turbo-molecular, sublimator, and mechanical. A pulsed bending magnet at the high energy end of the linac allowed both a polarized proton pulse to be injected to the ZGS, and a burst of H- beam pulses to be injected to the RCS.
In 1978 the first ever high energy polarized deuteron
beam[5] was accelerated. The deuterons were accelerated to 375
keV in the preaccelerator and to 25 MeV by the 50 MeV linac. The
rf level and quadrupole magnet currents used for accelerating
deuterons in the 2 mode were essentially the same as normally
used for protons. Normal tuneup resulted in a deuteron transmission
through the linac of about 25%.
Proton Therapy
In 1983 the Ho beam resulting from gas
stripping at the high energy end of the linac was studied as a
possible proton therapy facility at Argonne[6]. The H-
beam was separated from the Ho beam by a bending magnet
and the Ho beam drifted through the beamline to the
previous ZGS area. An intensity collimator and halo foil reduced
the lower energy components produced by gas stripping earlier
in the linac. The beam was then converted to H+ by
passing through a thin foil. It then passed through a spectrometer
magnet into the experimental enclosure.
Strategic Defense Initiative
One of the objectives of the Strategic Defense Initiative
(SDI) was to put a medium energy (50-200 MeV) H- linac
into space to evaluate the promise of Neutral Particle Beam (NPB)
devices. The beam intensity and quality requirements were far
beyond those of any operating linac so a great deal of research
was required. The only operating H- linac in this energy
range was at IPNS, so the Neutral Particle Beam Test Stand (NPBST)[7]
was developed in 1986. Two beam lines were constructed in the
old ZGS tunnel. The first line provided basic physics information
on beam diagnostics and high energy neutralization devices. The
second line was used to study the magnetic optics required to
produce large diameter beams with low divergence.
Figure 2 shows the availability ratio (ratio of beam
hours available to beam hours scheduled) for the entire RCS accelerator
system. As can be seen the yearly average is around 95%. The availability
of the linac alone averages above 99%. Scheduled and operating
time are shown in Figure 3. For several years budget constraints
have limited operation to less than 20 weeks per year. The Scientific
Facilities Initiative (SFI) funding included in the FY 1996 budget
provides for an increase in operating time in 1996 to 25 weeks
and should eventually result in an operating schedule of up to
32 weeks per year.
The authors wish to thank the entire linac crew for
their diligent machine maintenance and improvements. Without their
efforts, the continuing high availability numbers for the linac
would be impossible.
[1] A. Rauchas, F. Brumwell, and G. Volk, "Commissioning
of the Intense Pulsed Neutron Source Accelerator", IEEE Transactions
on Nuclear Science, Vol. NS-26, p3006, (1979).
[2] V. Stipp, A. DeWitt, and J. Madsen, "A Brighter
H- Source for the Intense Pulsed Neutron Source Accelerator System",
IEEE Transactions on Nuclear Science, Vol. NS-30, p2743, (1983).
[3] J. Fasola, "H- Source Development
at ANL", IEEE Transactions on Nuclear Science, Vol. NS-24,
p1597, (1977).
[4] E. Parker, "History of the Polarized Beam",
AIP Conference Proceedings No. 60, p143, (1979).
[5] E. Parker, "High Energy Polarized Deuterons
at the Argonne National Laboratory Zero Gradient Synchrotron",
IEEE Transactions on Nuclear Science, Vol. NS-26, p3200, (1979).
[6] S. Kramer, "A Low Cost/Low Intensity 50
MeV Proton Irradiation Facility", IEEE Transactions on Nuclear
Science, Vol. NS-32, p3311, (1985).
[7] C. Fink, et al., "NPBTS--Overview and Capabilities",
Proceedings of the 1989 Particle Accelerator Conference, p295,
(1989).