Linac96

ISOTOPE PRODUCTION FOR MEDICAL AND TECHNICAL USE AT MOSCOW MESON FACTORY LINAC

S.K.Esin, V.M.Kokhanyuk, L.V. Kravchuk, P.N.Ostroumov, V.L.Serov, B.L.Zhuikov

Institute for Nuclear Research, Moscow, 117312, Russia

Abstract

At the moment the Moscow Meson Factory Linac provides an average proton beam current up to 65 A. The linac consists of a 26 bending magnet and transport channel in order to extract the proton beam with an intermediate energy of 158.6 MeV to a facility for high level radioisotope production. Production of 82Sr, 109Cd, 22Na, 68Ge and other isotopes for medical and industrial applications is in progress now. The paper describes the isotope production facility including the beam channel, target equipment, beam tuning procedure as well as some methods, results and plans of the isotope production program.

Introduction

A new powerful linear accelerator operates at the Institute for Nuclear Research of the Academy of Sciences of Russia in Troitsk (near Moscow). Though the full proton energy and project intensity of the linac for fundamental science are not achieved yet, there is an intense beam with the energy of 160 MeV or lower that is used for production of isotopes for medical radiodiagnostic and technical applications.

Isotope Production Facility

A new powerful Isotope Production Facility (IPF) and a laboratory was constructed for isotope production. A general layout of the IPF is shown in the Fig. 1. The facility can accept a beam current of about 100 A which is planned to extend up to 500 A in future. The IPF comprises a production target, 333 m3 iron shielding, target holder inside the shielding, water cycling cooling system for the irradiated target, manipulator for target handling and operation with high activity and the beam control system (see Fig. 1). Two 1.5 m long and 14 cm diameter tubes are inserted into the shielding iron cube: one for beam delivery and another for the target delivery into the shielding cube. Due to the space restriction the tubes are located at 26 angle to each other.

The target cell containing three targets is shown in Fig. 2. A graphite collimator comprising four segments is mounted in this tube very near to the beam inlet window and the target. Each graphite segment is equipped with a thermocouple and is fine welded to a water cooled stainless steel radiator. Measurements of the temperature distribution between the collimator segments, cooling water flow and temperature and beam current provide an opportunity to calculate beam losses on the collimator during the bombardment as well as the beam position directly before the target.


Fig. 1. Layout of the isotope production facility.

1 : Beam diagnostic systems;

2 : Iron shielding cube; Iron shielding cube;

3 : Target sliding into the cube;

4 : Manipulator for target handling;

5 : Lead window system;

6 : Main exit;

7 : Heat exchanger;

8 : Buffer vessel of cycling water cooling system;

9 : Main and reserve pumps;

10 : Ion exchange filters;

11 : Storage of used radioactive filters;

12 : Tambour with hatch for radioisotope product removal;

13 : Reserve exit.

The target holder (position 2 in Fig. 2) is made of hard graphite (to minimize an activation) and has three pairs of sliding slots which are used to insert and hold the targets. Thereby, three targets with different proton energies can be bombarded simultaneously, or a graphite absorber for the beam energy adjustment can be used. All-metal targets as well as the shells are filled with low melting temperature or water-soluble metals (rubidium, indium, gallium, etc.). The target holder is fixed at the edge of a 2 m stainless steel rod which is remotely moved by a cart on the supporting metal frame towards or away from the shielding cube providing the target insertion or removal.

A number of radionuclides can be produced at the facility (see Table 1). Some of the radionuclides have been successfully produced. First was strontium-82. This radionuclide is used for a new promising method of the medical diagnostics - Positron Emission Tomography (PET) - developed in North America and being developed in Europe. The half life period of this isotope is 25 days which allows a safe domestic as well as global transportation. There are not so many high intensity accelerators in the world possessing the relevant proton beam energy to produce strontium-82 besides the INR accelerator.

Fig. 2. Target irradiation chamber.

1 : Stainless steel rod;

2 : Target holder;

3 : Slots with screws for holder moving

4 : Target thermocouple in stainless steel shell;

5 : Thin targets;

6 : Main rubidium target in stainless steel shell;

7 : Four collimator thermocouples;

8 : Vacuum window made from stainless steel;

9 : Graphite collimator;

10 : Stainless steel shell as a radiator of graphite collimator.

INR together with Canadian National Meson Facility TRIUMF has developed a new effective method for strontium-82 production from thick targets of metallic rubidium. A method of radiochemical isolation of radiostrontium from metallic rubidium targets is also developed. The latter allows the use of high intensity proton beams which provide a production of large amounts of strontium-82. The radiochemical isolation of strontium from the bombarded rubidium targets is provided by a new facility for radiochemical treatment - "Cyclotron" Company located at Obninsk, Russia. The purity of the product in this method is much better than in ordinary productions from other company.

Many other isotopes for medical, technical and scientific use are produced at the INR IPF: sodium-22 from magnesium or aluminum targets, cadmium-109 from indium targets and germanium-68 from gallium targets. In near future we plan to produce also palladium-103 from a silver target, copper-67 from a zinc target, titanium-44 from a scandium target, thallium from a lead target, and iodine-123, 122, 121 from a sodium iodide target.



Table 1. List of available radionuclides at INR Isotope Facility

Radio-nuclide
T1/2
Target
Energy range, MeV
Period of bomb,hours
Activity,Ci
Sr-82
25.3d
Rb
100-41
250
15
Na-22
2.6 y
Al
150-35
250
1
Mg
150-35
250
2
Cd-109
453 d
In
150-60
250
2
Pd-103
17 d
Ag
150-50
100
100
Cu-67
62 hr
Zn
150-70
100
30
Co-57
271 d
Ni
28-15
250
1
Ti-44
47.3y
Sc
60-20
250
0.01
Ge-68
288 d
Ga
50-15
250
0.5
Tl-201
73 hr
Pb
60-52
25
6
Pb
70-55
25
4

Beam Delivery to IPF

The high intensity operation of the IPF requires reliable high intensity beam transport to the target. For the effective target radiation the typical beam diameter at the target position is 20 mm (98% of particles). In order to avoid particle losses the beam position as well as beam size must be controlled during the irradiation.

The envelopes of 158.6 MeV beam along the beam line are shown in Fig. 3. The beam diagnostics at this section include a wire scanner (WS) and a pair of harps. One of the harps is installed permanently, directly before the shielding and beam profiles can be observed on-line during the beam production for the IPF. In addition the segmented graphite collimator temperatures are extremely useful for beam quality control at the target (see Fig. 2). The operational experience shows that along the beam line there is a local radiation of the beam pipe due to the beam halo which is mainly determined by momentum dispersion. Initially the accelerator is tuned well in order to operate with a beam loss level below 0.3% at the section between the 100 MeV part to the target area. The main aspects of the beam tuning have been discussed in ref. [2]. However long term operation causes a slow drift of the beam parameters at the target position. Therefore beam parameters are measured on-line by using WS, harp and collimator temperatures. Recently to control beam losses, control in four transverse directions at the critical point along the beam line neutron detectors have been installed (PM in Fig.3). During the last few years essential work has been done to improve the fast protection system in order to avoid beam spill on equipment.


Fig. 3. Beam transport to IPF.

D : Focusing doublet, HVS : Horizontal and vertical steering, BM : Bending magnet,

LM : Beam loss monitors,

PM : Beam position measurement by the help of neutron detectors,

T : Target H : Harp, WS : Wire scanner,

Conclusion

The isotope production facility is under operation at INR on the bases of high intensity 158.6 MeV proton beam. During the last two years the possibility of production of 82Sr and 109Cd has been successfully demonstrated. A high reliability of the whole procedure of isotope production including beam delivery, target irradiation as well as chemical treatment of the target has been proved.